The HELIOS AMX5000 aspirating smoke detector is a
highly sensitive active smoke detection system of the latest
generation. In addition to monitoring advance signals and
contamination, it also provides the option of the user-specific
adjustment of the sensitivity. The powerful fan enables up
to 50 sampling holes with 300 m (984 ft) pipe system per
smoke sensor. The HELIOS AMX5000 is even able to detect
the smallest smoldering fires and can be used practically
everywhere. Version AMX5001: basic device with simple
display. For 1 sampling pipe and 1 smoke sensor.
Application
Aspirating smoke detector for the detection of smoke
particles by air sampling. The system takes on air sampling
probe in from the monitoring area via a pipe system.
Typical applications
- Equipment monitoring:
IT systems, electrical distributors, switch cabinets, etc.
- Room monitoring: IT rooms, clean rooms, warehouses,
high rack storage areas, hollow floors, protection of cultural
assets, transformer stations, etc.
Included in delivery
1 Aspirating smoke detector AMX5001 908095
Not included in delivery
Smoke sensor OMX5005,
Spare parts
Note
The HELIOS AMX5000 can be connected to a higher-level
fire alarm panel via dry changeover contacts. The HELIOS
AMX5000 can be integrated into a fire detection system
FMZ 5000 or Clunid with Loop AP via modules. Indication
and operation are thus possible at the control panel.
Product features
• Autolearning function
• Separate airflow monitoring with one or two aspiration lines
• Adjustable sensitivity of 0.002 - 10 % / m
(0.0006 - 3.049 % / ft)
• High sampling power (high negative pressure of 400 Pa)
• Highly sensitive smoke sensors with contamination
compensation for use in critical environments
• Full integration into fire alarm system FMZ 5000
or Clunid
Approvals / marking
The HELIOS AMX5000 aspirating smoke detector is a
highly sensitive active smoke detection system of the latest
generation. In addition to monitoring advance signals and
contamination, it also provides the option of the user-specific
adjustment of the sensitivity. The powerful fan enables up
to 50 sampling holes with 300 m (984 ft) pipe system per
smoke sensor. The HELIOS AMX5000 is even able to detect
the smallest smoldering fires and can be used practically
everywhere. Version AMX5001: basic device with simple
display. For 1 sampling pipe and 1 smoke sensor.
Application
Aspirating smoke detector for the detection of smoke
particles by air sampling. The system takes on air sampling
probe in from the monitoring area via a pipe system.
Typical applications
- Equipment monitoring:
IT systems, electrical distributors, switch cabinets, etc.
- Room monitoring: IT rooms, clean rooms, warehouses,
high rack storage areas, hollow floors, protection of cultural
assets, transformer stations, etc.
Included in delivery
1 Aspirating smoke detector AMX5001 908095
Not included in delivery
Smoke sensor OMX5005,
0.5 % /m - 10 % / m (0.152 % / ft - 3.049 % / ft) Smoke sensor OMX5010, | 908099 |
0.1 % / m - 10 % / m (0.030 % / ft - 3.049 % / ft) Smoke sensor OMX5020, | 908100 |
0.02 % / m - 10 % / m (0.006 % / ft - 3.049 % / ft) | 908101 |
Relay module KMX5005 RK | 908103 |
Memory module MMX5005 | 908104 |
Configuration software HELIOS Config | 908105 |
Project planning software HELIOS PipeCalc | 908106 |
Case fastener (4 pieces) | 909434 |
Air flow sensor HELIOS AMX5000 | 917702 |
The HELIOS AMX5000 can be connected to a higher-level
fire alarm panel via dry changeover contacts. The HELIOS
AMX5000 can be integrated into a fire detection system
FMZ 5000 or Clunid with Loop AP via modules. Indication
and operation are thus possible at the control panel.
Product features
• Autolearning function
• Separate airflow monitoring with one or two aspiration lines
• Adjustable sensitivity of 0.002 - 10 % / m
(0.0006 - 3.049 % / ft)
• High sampling power (high negative pressure of 400 Pa)
• Highly sensitive smoke sensors with contamination
compensation for use in critical environments
• Full integration into fire alarm system FMZ 5000
or Clunid
Approvals / marking
Technical specifications | |
Operating voltage | 10.5 - 30 V DC |
Rated voltage | 24 V DC |
Alarm sensitivity | 0.02 % / m - 10 % / m (0.006 % / ft - 3.049 % / ft) |
Pre-Alarm signals 1,2,3 | 0.002 - 10 % / m (0.0006 % / ft - 3.049 % / ft, programmable in increments of 10 % |
Max. current consumption | Inactive/fault approx. 340 mA Alarm I approx. 390 mA |
Number of relays | 3 |
Max. contact load | 50 V DC, 1 A |
IP rating | IP 54 |
Ambient temperature | -30 °C to +60 °C (-22 °F to +140 °F) |
Intake pressure | > 400 Pa (power level 5) |
Suction noise at fan level 3 (standard) | 43 dB (A) |
Number of installation spaces for add-on modules | 4 |
Sampling pipe | Plug-in system 25 mm (0.98 inch) |
Relative humidity | max. 95 %, temporarily without condensation 70 %, constantly |
Enclosure material | ABS-Blend, UL 94-V0 |
Specification according to | EN 54-20, classes A, B and C |
Weight | 3.85 kg (8.5 lbs) |
Dimensions | 265 x 397 x 146 mm (WxHxD) 10.4 x 15.6 x 5.8 inch (WxHxD) |