CẢNH BÁO SỚM VIKING

AMX5001 
Part no.: 908095
The HELIOS AMX5000 aspirating smoke detector is a
highly sensitive active smoke detection system of the latest
generation. In addition to monitoring advance signals and
contamination, it also provides the option of the user-specific
adjustment of the sensitivity. The powerful fan enables up
to 50 sampling holes with 300 m (984 ft) pipe system per
smoke sensor. The HELIOS AMX5000 is even able to detect
the smallest smoldering fires and can be used practically
everywhere. Version AMX5001: basic device with simple
display. For 1 sampling pipe and 1 smoke sensor.
Application
Aspirating smoke detector for the detection of smoke
particles by air sampling. The system takes on air sampling
probe in from the monitoring area via a pipe system.
Typical applications
- Equipment monitoring:
IT systems, electrical distributors, switch cabinets, etc.
- Room monitoring: IT rooms, clean rooms, warehouses,
high rack storage areas, hollow floors, protection of cultural
assets, transformer stations, etc.
Included in delivery
1 Aspirating smoke detector AMX5001 908095
Not included in delivery
Smoke sensor OMX5005,
0.5 % /m - 10 % / m (0.152 % / ft - 3.049 % / ft)
Smoke sensor OMX5010,
908099

0.1 % / m - 10 % / m (0.030 % / ft - 3.049 % / ft)
Smoke sensor OMX5020,
908100

0.02 % / m - 10 % / m (0.006 % / ft - 3.049 % / ft) 908101
Relay module KMX5005 RK 908103
Memory module MMX5005 908104
Configuration software HELIOS Config 908105
Project planning software HELIOS PipeCalc 908106
Spare parts
Case fastener (4 pieces) 909434
Air flow sensor HELIOS AMX5000 917702
Note
The HELIOS AMX5000 can be connected to a higher-level
fire alarm panel via dry changeover contacts. The HELIOS
AMX5000 can be integrated into a fire detection system
FMZ 5000 or Clunid with Loop AP via modules. Indication
and operation are thus possible at the control panel.
Product features
• Autolearning function
• Separate airflow monitoring with one or two aspiration lines
• Adjustable sensitivity of 0.002 - 10 % / m
(0.0006 - 3.049 % / ft)
• High sampling power (high negative pressure of 400 Pa)
• Highly sensitive smoke sensors with contamination
compensation for use in critical environments
• Full integration into fire alarm system FMZ 5000
or Clunid
Approvals / marking
Technical specifications
Operating voltage 10.5 - 30 V DC
Rated voltage 24 V DC
Alarm sensitivity 0.02 % / m - 10 % / m
(0.006 % / ft - 3.049 % / ft)
Pre-Alarm signals 1,2,30.002 - 10 % / m
(0.0006 % / ft - 3.049 % / ft,
programmable in increments of 10 %
Max. current consumption Inactive/fault approx. 340 mA
Alarm I approx. 390 mA
Number of relays 3
Max. contact load 50 V DC, 1 A
IP rating IP 54
Ambient temperature -30 °C to +60 °C
(-22 °F to +140 °F)
Intake pressure > 400 Pa (power level 5)
Suction noise at fan level 3
(standard)
43 dB (A)
Number of installation spaces
for add-on modules
4
Sampling pipe Plug-in system 25 mm (0.98 inch)
Relative humiditymax. 95 %,
temporarily without condensation
70 %, constantly
Enclosure material ABS-Blend, UL 94-V0
Specification according to EN 54-20, classes A, B and C
Weight 3.85 kg (8.5 lbs)
Dimensions 265 x 397 x 146 mm (WxHxD)
10.4 x 15.6 x 5.8 inch (WxHxD)

Nhà phân phối: Công ty Cổ phần Công Nghệ Fire Việt Nam (VNFT., JSC)

Liên hệ: Mrs Liên: 0911204078
Email: sales.vietfiretechs@gmail.com